Pool heat pump sizing | Next working day delivery from £7.80 | Pump station maintenance | Click & collect from Bury St Edmunds | Rated excellent on TrustPilot
We are rated excellent on Trustpilot

ProTeam XXS Plug & Play Heat Pump for Above Ground Swimming Pools

ProTeam XXS Plug & Play Heat Pump for Above Ground Swimming Pools

ProTeam XXS heat pumps are ideal for Summer only heating of small above-ground pools, their low flow rate requirement makes them perfect for use with the pump and filter sets supplied with smaller pools.

Setup of the ProTeam XXS is straightforward, simply plug the heat pump into an outdoor socket using the fitted mains cable and plug, connect the hoses from your pool’s filter, switch on and set your desired water temperature.

Please note that the ProTeam XXS only operates in ambient air temperatures above 10 degrees* and is designed for June to August use, if you would like to extend your swimming season please speak to us about selecting a larger heat pump.

Important: the heat output on the XXS models are as follows; up to 3.05kW (XXS3), 4kW (XXS4) and 5.6kW (XXS6) of heat for every kW of energy used, this is based on air temperature of 26°C, water temperature of 26°C and target temperature of 27-28°C, the cooler the air temperature the lower the heat output, therefore a target temperature of 28°C will be more difficult to achieve on a larger pool in cooler weather, please speak to us if you would like help sizing a heat pump.

Not sure what size heat pump you need?
Use our sizing guide or request a free quote

Key features

Compact plug and play heat pumps that are suitable for Summer season (June to August) heating of small above-ground pools

Up to 3.05kW (XXS3), 4kW (XXS4) and 5.6kW (XXS6) of heat output at air temperature of 26°C, water temperature of 26°C and target temperature of 27-28°C

Up to 2.51kW (XXS3), 3.1kW (XXS4) and 4.95kW (XXS6) of heat output at air temperature of 15°C, water temperature of 26°C and target temperature of 27-28°C

Ideal for Intex and Bestway above-ground pools that come supplied with filter pumps, maximum flow rate required 3.0m³/h (3,000 l/h)

Summer only (June to August), suitable for use when the air temperature is above 10°C (*please note unit will stop running if air temperature falls below 10 degrees)

Maximum input power 1.55kW, maximum input current 7.0A

Plug and play, comes with mains cable, RCD and UK plug, suitable for use in outdoor sockets

1 inch FBSP water connections, 1 inch to 32/38mm hose tails and clips included

R32 Refrigerant

Off white steel casing with black lid and base

Titanium heat exchanger, chlorine and salt resistant

Two year warranty, seven years on compressor and heat exchanger (parts only after first two years)

Downloads

Specifications

Heating Capacity A26/W26
3.05 kW
COP
5.45
Heating Capacity A15/W26
2.51 kW
COP
4.53
Input Power (max.)
0.95 kW
Input Current
4.4A
Voltage
230v
Noise Level
28dB(A)
Refrigerant
R32
Water Connections
1 inch FBSP (32/38mm hose tails included)
Nominal Flow
1.5 m³/h (1,500 l/h)
Dimensions (L x W x H)
380mm x 280mm x 350mm
Weight
18Kg
Heating Capacity A26/W26
4.0 kW
COP
5.45
Heating Capacity A15/W26
3.10 kW
COP
4.52
Input Power (max.)
1.28 kW
Input Current
5.8A
Voltage
230v
Noise Level
29dB(A)
Refrigerant
R32
Water Connections
Hose tails included
Nominal Flow
2.0 m³/h (2,000 l/h)
Dimensions (L x W x H)
380mm x 280mm x 350mm
Weight
20Kg
Heating Capacity A26/W26
5.6 kW
COP
5.43
Heating Capacity A15/W26
4.95 kW
COP
4.54
Input Power (max.)
1.55 kW
Input Current
7.0A
Voltage
230v
Noise Level
29dB(A)
Refrigerant
R32
Water Connections
Hose tails included
Nominal Flow
3.0 m³/h (3,000 l/h)
Dimensions (L x W x H)
420mm x 360mm x 436mm
Weight
24Kg

What is COP?

COP stands for Coefficient of Performance

COP is quoted as a number, such as 5.6

For each kW of energy input, 5.6 x kW would be output

The higher the output, the lower the running costs

Installation

Heat loss

If you are thinking of heating your pool you should cover the pool when not in use as 80% of heat loss occurs through surface evaporation, a separate solar or bubble cover is a worthwhile investment if you don’t have an existing cover.

With an above ground pool it is especially important to keep it covered as these pools are not well insulated against heat loss – additional insulation around the sides and bottom of an above-ground pool can help to retain valuable heat – in fact properly insulating your pool can extend your season or even reduce the size of heat pump required.

All models are fitted with a mains cable, RCD and plug as standard, making them suitable for outdoor sockets, this cable can be removed and the unit can be hardwired if required.

Water inlet and outlet connections are 1 inch FBSP, 1 inch to 32/38mm hose tails and clips included.

If the flow rate through your heat pump is too high it can take longer to heat your pool or you may struggle to achieve your desired temperature, our bypass kit for above ground pools optimises the flow rate to maximise the heat transfer to your pool water. A bypass kit also allows the circulation and filtering of pool water without heating and for winterising your heat pump.

Your ProTeam XXS swimming pool heat pump should always be installed outside, restrictions on air flow around a heat pump such as dense vegetation or solid surfaces such as sheds, fences or walls will lead to a drop in efficiency and heating ability, it especially important that cooled air can be properly dispersed away from the unit.

While the casing provides protection from the weather, the XXS is intended for Summer use only, the unit should be disconnected and stored in a shed or garage when not in use over the Winter.

The manufacturer literature may state that the heat pump should be positioned above the waterline, the assumption being that pools are in-ground, therefore the heat pump would sit at ground level.

If you have an above-ground pool please also position your heat pump at ground level (therefore below the waterline), there is no need to elevate the heat pump.

Product Description

ProTeam XXS heat pumps are ideal for Summer only heating of small above-ground pools, their low flow rate requirement makes them perfect for use with the pump and filter sets supplied with smaller pools.

Setup of the ProTeam XXS is straightforward, simply plug the heat pump into an outdoor socket using the fitted mains cable and plug, connect the hoses from your pool’s filter, switch on and set your desired water temperature.

Please note that the ProTeam XXS only operates in ambient air temperatures above 10 degrees* and is designed for June to August use, if you would like to extend your swimming season please speak to us about selecting a larger heat pump.

Important: the heat output on the XXS models are as follows; up to 3.05kW (XXS3), 4kW (XXS4) and 5.6kW (XXS6) of heat for every kW of energy used, this is based on air temperature of 26°C, water temperature of 26°C and target temperature of 27-28°C, the cooler the air temperature the lower the heat output, therefore a target temperature of 28°C will be more difficult to achieve on a larger pool in cooler weather, please speak to us if you would like help sizing a heat pump.

ProTeam XXS Plug & Play Heat Pump for Above Ground Swimming Pools

ProTeam XXS Plug & Play Heat Pump for Above Ground Swimming Pools

ProTeam XXS heat pumps are ideal for Summer only heating of small above-ground pools, their low flow rate requirement makes them perfect for use with the pump and filter sets supplied with smaller pools.

Setup of the ProTeam XXS is straightforward, simply plug the heat pump into an outdoor socket using the fitted mains cable and plug, connect the hoses from your pool’s filter, switch on and set your desired water temperature.

Please note that the ProTeam XXS only operates in ambient air temperatures above 10 degrees* and is designed for June to August use, if you would like to extend your swimming season please speak to us about selecting a larger heat pump.

Important: the heat output on the XXS models are as follows; up to 3.05kW (XXS3), 4kW (XXS4) and 5.6kW (XXS6) of heat for every kW of energy used, this is based on air temperature of 26°C, water temperature of 26°C and target temperature of 27-28°C, the cooler the air temperature the lower the heat output, therefore a target temperature of 28°C will be more difficult to achieve on a larger pool in cooler weather, please speak to us if you would like help sizing a heat pump.

Not sure what size heat pump you need?
Use our sizing guide or request a free quote

Key features

Compact plug and play heat pumps that are suitable for Summer season (June to August) heating of small above-ground pools

Up to 3.05kW (XXS3), 4kW (XXS4) and 5.6kW (XXS6) of heat output at air temperature of 26°C, water temperature of 26°C and target temperature of 27-28°C

Up to 2.51kW (XXS3), 3.1kW (XXS4) and 4.95kW (XXS6) of heat output at air temperature of 15°C, water temperature of 26°C and target temperature of 27-28°C

Ideal for Intex and Bestway above-ground pools that come supplied with filter pumps, maximum flow rate required 3.0m³/h (3,000 l/h)

Summer only (June to August), suitable for use when the air temperature is above 10°C (*please note unit will stop running if air temperature falls below 10 degrees)

Maximum input power 1.55kW, maximum input current 7.0A

Plug and play, comes with mains cable, RCD and UK plug, suitable for use in outdoor sockets

1 inch FBSP water connections, 1 inch to 32/38mm hose tails and clips included

R32 Refrigerant

Off white steel casing with black lid and base

Titanium heat exchanger, chlorine and salt resistant

Two year warranty, seven years on compressor and heat exchanger (parts only after first two years)

Downloads

Specifications

Heating Capacity A26/W26
3.05 kW
COP
5.45
Heating Capacity A15/W26
2.51 kW
COP
4.53
Input Power (max.)
0.95 kW
Input Current
4.4A
Voltage
230v
Noise Level
28dB(A)
Refrigerant
R32
Water Connections
1 inch FBSP (32/38mm hose tails included)
Nominal Flow
1.5 m³/h (1,500 l/h)
Dimensions (L x W x H)
380mm x 280mm x 350mm
Weight
18Kg
Heating Capacity A26/W26
4.0 kW
COP
5.45
Heating Capacity A15/W26
3.10 kW
COP
4.52
Input Power (max.)
1.28 kW
Input Current
5.8A
Voltage
230v
Noise Level
29dB(A)
Refrigerant
R32
Water Connections
Hose tails included
Nominal Flow
2.0 m³/h (2,000 l/h)
Dimensions (L x W x H)
380mm x 280mm x 350mm
Weight
20Kg
Heating Capacity A26/W26
5.6 kW
COP
5.43
Heating Capacity A15/W26
4.95 kW
COP
4.54
Input Power (max.)
1.55 kW
Input Current
7.0A
Voltage
230v
Noise Level
29dB(A)
Refrigerant
R32
Water Connections
Hose tails included
Nominal Flow
3.0 m³/h (3,000 l/h)
Dimensions (L x W x H)
420mm x 360mm x 436mm
Weight
24Kg

What is COP?

COP stands for Coefficient of Performance

COP is quoted as a number, such as 5.6

For each kW of energy input, 5.6 x kW would be output

The higher the output, the lower the running costs

Installation

Heat loss

If you are thinking of heating your pool you should cover the pool when not in use as 80% of heat loss occurs through surface evaporation, a separate solar or bubble cover is a worthwhile investment if you don’t have an existing cover.

With an above ground pool it is especially important to keep it covered as these pools are not well insulated against heat loss – additional insulation around the sides and bottom of an above-ground pool can help to retain valuable heat – in fact properly insulating your pool can extend your season or even reduce the size of heat pump required.

All models are fitted with a mains cable, RCD and plug as standard, making them suitable for outdoor sockets, this cable can be removed and the unit can be hardwired if required.

Water inlet and outlet connections are 1 inch FBSP, 1 inch to 32/38mm hose tails and clips included.

If the flow rate through your heat pump is too high it can take longer to heat your pool or you may struggle to achieve your desired temperature, our bypass kit for above ground pools optimises the flow rate to maximise the heat transfer to your pool water. A bypass kit also allows the circulation and filtering of pool water without heating and for winterising your heat pump.

Your ProTeam XXS swimming pool heat pump should always be installed outside, restrictions on air flow around a heat pump such as dense vegetation or solid surfaces such as sheds, fences or walls will lead to a drop in efficiency and heating ability, it especially important that cooled air can be properly dispersed away from the unit.

While the casing provides protection from the weather, the XXS is intended for Summer use only, the unit should be disconnected and stored in a shed or garage when not in use over the Winter.

The manufacturer literature may state that the heat pump should be positioned above the waterline, the assumption being that pools are in-ground, therefore the heat pump would sit at ground level.

If you have an above-ground pool please also position your heat pump at ground level (therefore below the waterline), there is no need to elevate the heat pump.

Bypass Kit

Universal Heat Pump Bypass Kit for Above Ground Pools
Hydro-Fit Universal Heat Pump Bypass Kit

103 in stock Available for delivery from next working day

-
+
£70.50 £58.75 ex vat

Fittings

38mm Black Vac Pool Hose
Black 38mm Vac Hose (per metre)

440 in stock Available for delivery from next working day

-
+
£2.50 £2.08 ex vat
Stainless Steel Hose Clip
Stainless Steel Hose Clip (Type W4, 9mm) - 30-45mm

146 in stock Available for delivery from next working day

-
+
£1 £0.83 ex vat

Accessories

Floating Thermometer
Floating Thermometer

36 in stock Available for delivery from next working day

-
+
£4.50 £3.75 ex vat
Product code: 73311 Category: Tag:

Payment methods we accept

Payment methods we accept

Delivery & collection

Small UK Mainland (under £100) - from next working day £7.80

Standard UK Mainland (under £300) - from next working day £12

Free UK Mainland (over £300) - from next working day

Channel Islands and Isle of Man £70 (3-4 days)

Isle of Wight £30 (2 days)

Lower Highlands £30 (2 days)

Upper Highlands (mainland) £30 (3-4 days)

Scottish Offshore £35 (5-7 days)

Need it in a hurry? You can order online and pick up your item(s) for FREE.

If it's in stock, you can pick it up the same day.

Collect from our Bury St Edmunds warehouse, Mon to Fri 9am to 5pm

Large and/or heavy items are dispatched on pallets

ALL heat pumps are dispatched on pallets

Delivery is to kerbside via lorry with tail lift

Pallet deliveries must be signed for

Parked cars, overhanging trees and narrow roads can prevent lorry access - please notify us of known access restrictions PRIOR to delivery

For full details see our delivery page

Description

ProTeam XXS heat pumps are ideal for Summer only heating of small above-ground pools, their low flow rate requirement makes them perfect for use with the pump and filter sets supplied with smaller pools.

Setup of the ProTeam XXS is straightforward, simply plug the heat pump into an outdoor socket using the fitted mains cable and plug, connect the hoses from your pool’s filter, switch on and set your desired water temperature.

Please note that the ProTeam XXS only operates in ambient air temperatures above 10 degrees* and is designed for June to August use, if you would like to extend your swimming season please speak to us about selecting a larger heat pump.

Important: the heat output on the XXS models are as follows; up to 3.05kW (XXS3), 4kW (XXS4) and 5.6kW (XXS6) of heat for every kW of energy used, this is based on air temperature of 26°C, water temperature of 26°C and target temperature of 27-28°C, the cooler the air temperature the lower the heat output, therefore a target temperature of 28°C will be more difficult to achieve on a larger pool in cooler weather, please speak to us if you would like help sizing a heat pump.

Not sure what size heat pump you need?
Use our sizing guide or request a free quote

Key features

Compact plug and play heat pumps that are suitable for Summer season (June to August) heating of small above-ground pools

Up to 3.05kW (XXS3), 4kW (XXS4) and 5.6kW (XXS6) of heat output at air temperature of 26°C, water temperature of 26°C and target temperature of 27-28°C

Up to 2.51kW (XXS3), 3.1kW (XXS4) and 4.95kW (XXS6) of heat output at air temperature of 15°C, water temperature of 26°C and target temperature of 27-28°C

Ideal for Intex and Bestway above-ground pools that come supplied with filter pumps, maximum flow rate required 3.0m³/h (3,000 l/h)

Summer only (June to August), suitable for use when the air temperature is above 10°C (*please note unit will stop running if air temperature falls below 10 degrees)

Maximum input power 1.55kW, maximum input current 7.0A

Plug and play, comes with mains cable, RCD and UK plug, suitable for use in outdoor sockets

1 inch FBSP water connections, 1 inch to 32/38mm hose tails and clips included

R32 Refrigerant

Off white steel casing with black lid and base

Titanium heat exchanger, chlorine and salt resistant

Two year warranty, seven years on compressor and heat exchanger (parts only after first two years)

Downloads

Specifications

Heating Capacity A26/W26
3.05 kW
COP
5.45
Heating Capacity A15/W26
2.51 kW
COP
4.53
Input Power (max.)
0.95 kW
Input Current
4.4A
Voltage
230v
Noise Level
28dB(A)
Refrigerant
R32
Water Connections
1 inch FBSP (32/38mm hose tails included)
Nominal Flow
1.5 m³/h (1,500 l/h)
Dimensions (L x W x H)
380mm x 280mm x 350mm
Weight
18Kg
Heating Capacity A26/W26
4.0 kW
COP
5.45
Heating Capacity A15/W26
3.10 kW
COP
4.52
Input Power (max.)
1.28 kW
Input Current
5.8A
Voltage
230v
Noise Level
29dB(A)
Refrigerant
R32
Water Connections
Hose tails included
Nominal Flow
2.0 m³/h (2,000 l/h)
Dimensions (L x W x H)
380mm x 280mm x 350mm
Weight
20Kg
Heating Capacity A26/W26
5.6 kW
COP
5.43
Heating Capacity A15/W26
4.95 kW
COP
4.54
Input Power (max.)
1.55 kW
Input Current
7.0A
Voltage
230v
Noise Level
29dB(A)
Refrigerant
R32
Water Connections
Hose tails included
Nominal Flow
3.0 m³/h (3,000 l/h)
Dimensions (L x W x H)
420mm x 360mm x 436mm
Weight
24Kg

What is COP?

COP stands for Coefficient of Performance

COP is quoted as a number, such as 5.6

For each kW of energy input, 5.6 x kW would be output

The higher the output, the lower the running costs

Installation

Heat loss

If you are thinking of heating your pool you should cover the pool when not in use as 80% of heat loss occurs through surface evaporation, a separate solar or bubble cover is a worthwhile investment if you don’t have an existing cover.

With an above ground pool it is especially important to keep it covered as these pools are not well insulated against heat loss – additional insulation around the sides and bottom of an above-ground pool can help to retain valuable heat – in fact properly insulating your pool can extend your season or even reduce the size of heat pump required.

All models are fitted with a mains cable, RCD and plug as standard, making them suitable for outdoor sockets, this cable can be removed and the unit can be hardwired if required.

Water inlet and outlet connections are 1 inch FBSP, 1 inch to 32/38mm hose tails and clips included.

If the flow rate through your heat pump is too high it can take longer to heat your pool or you may struggle to achieve your desired temperature, our bypass kit for above ground pools optimises the flow rate to maximise the heat transfer to your pool water. A bypass kit also allows the circulation and filtering of pool water without heating and for winterising your heat pump.

Your ProTeam XXS swimming pool heat pump should always be installed outside, restrictions on air flow around a heat pump such as dense vegetation or solid surfaces such as sheds, fences or walls will lead to a drop in efficiency and heating ability, it especially important that cooled air can be properly dispersed away from the unit.

While the casing provides protection from the weather, the XXS is intended for Summer use only, the unit should be disconnected and stored in a shed or garage when not in use over the Winter.

The manufacturer literature may state that the heat pump should be positioned above the waterline, the assumption being that pools are in-ground, therefore the heat pump would sit at ground level.

If you have an above-ground pool please also position your heat pump at ground level (therefore below the waterline), there is no need to elevate the heat pump.

We use cookies to offer you a better browsing experience and to allow third parties to customise the marketing content you see across websites and social media