Remora Mini 3kW Plug & Play Heat Pump for Small Above Ground Swimming Pools

Product Description

The Remora Mini 3kW Plug & Play heat pump is perfect for heating small above-ground pools (<20m³) from June to August thanks to it's compact size and plug and play connectivity.

Setup of the Remora Mini is straightforward, simply plug the heat pump into an outdoor socket using the fitted mains cable and plug, connect the 32mm or 38mm hoses from your pool’s filter, switch on and set your desired water temperature.

Please note that the Remora Mini only operates in ambient air temperatures above 12 degrees, if the air temperature falls below this the unit will shut down.

Special offer available while stocks last, all units are brand new, boxed, and come complete with the full manufacturer’s warranty

Not sure what size heat pump you need?
Use our sizing guide or request a free quote

Key features

3kW heating capacity for June to August use on small pools up to 20m³

Mini design with compact footprint for easier placement, only 397mm high, 447mm wide and 320mm deep

Plug and Play convenience – fitted with 2.8m mains cable, RCD and UK plug – suitable for outdoor socket

32mm/38mm hose tail connectors

High efficiency performance, COP of 5.44, up to 3.21kW of heat for every kW used

Recommended for use in ambient temperatures above 12 degrees

Easy digital temperature control with LCD display

Auto operation and timer function

Quiet running, less than 32dB(A) at 10m

R32 gas for environmentally friendly operation

Aluminium evaporator with anti-corrosion Hydrophilic bluefin treatment

Flow switch prevents damage to the unit in event of no or low flow

Downloads

Specifications

Heating Capacity A26/W26
3.21 kW
Power Input A24/W26
0.59kW
COP A24/W26
5.44
Heating Capacity A15/W26
2.12 kW
Power Input A15/W26
0.52 kW
COP A15/W26
4.06
Max. Input Power
0.68 kW
Max. Current
3.09A
Electrical connection
2.8m cable, RCD and UK plug fitted
Voltage
230V
Refrigerant
R32
Noise Level (10m)
<32dB(A)
Fan Direction
Horizontal
Water Connections
32mm/38mm hose tail
Dimensions (L x W x H)
447mm x 320mm x 397mm
Nominal flow
1.30 m³/h

What is COP?

COP stands for Coefficient of Performance

COP is quoted as a number, such as 5.6

For each kW of energy input, 5.6 x kW would be output

The higher the output, the lower the running costs

Installation

If you are thinking of heating your pool you should cover the pool when not in use as 80% of heat loss occurs through surface evaporation, a separate solar or bubble cover is a worthwhile investment if you don’t have an existing cover.

With an above ground pool it is especially important to keep it covered as these pools are not well insulated against heat loss – additional insulation around the sides and bottom of an above-ground pool can help to retain valuable heat – in fact properly insulating your pool can extend your season or even reduce the size of heat pump required.

The Remora Mini 3kW is fitted with a 2.8m mains cable, RCD and plug as standard, making it suitable for outdoor sockets, this cable can be removed and the unit can be hardwired if required.

Water inlet and outlet connections are 32mm/38mm hose tail connectors.

If the flow rate through your heat pump is too high it can take longer to heat your pool or you may struggle to achieve your desired temperature, our bypass kit for above ground pools optimises the flow rate to maximise the heat transfer to your pool water. A bypass kit also allows the circulation and filtering of pool water without heating and for winterising your heat pump.

Your Remora Mini swimming pool heat pump should always be installed outside, restrictions on air flow around a heat pump such as dense vegetation or solid surfaces such as sheds, fences or walls will lead to a drop in efficiency and heating ability, it especially important that cooled air can be properly dispersed away from the unit.

While manufactured from high-quality materials including a corrosion resistant case, with a rotary compressor and an aluminium evaporator with corrosion resistant Hydrophilic bluefin treatment, the Mini is intended for Summer use only, the unit should be disconnected and stored in a shed or garage when not in use over the Winter.

The manufacturer literature may state that the heat pump should be positioned above the waterline, the assumption being that pools are in-ground, therefore the heat pump would sit at ground level.

If you have an above-ground pool please also position your heat pump at ground level (therefore below the waterline), there is no need to elevate the heat pump.

Two year parts and labour (return to base)

Seven years on the compressor and heat exchanger (parts only after year three)

Remora brand is exclusive to Automated Environmental Systems

Product Description

The Remora Mini 3kW Plug & Play heat pump is perfect for heating small above-ground pools (<20m³) from June to August thanks to it's compact size and plug and play connectivity.

Setup of the Remora Mini is straightforward, simply plug the heat pump into an outdoor socket using the fitted mains cable and plug, connect the 32mm or 38mm hoses from your pool’s filter, switch on and set your desired water temperature.

Please note that the Remora Mini only operates in ambient air temperatures above 12 degrees, if the air temperature falls below this the unit will shut down.

Special offer available while stocks last, all units are brand new, boxed, and come complete with the full manufacturer’s warranty

Remora Mini 3kW Plug & Play Heat Pump for Small Above Ground Swimming Pools

Remora Mini 3kW Plug & Play Heat Pump for Small Above Ground Swimming Pools

Product Description

The Remora Mini 3kW Plug & Play heat pump is perfect for heating small above-ground pools (<20m³) from June to August thanks to it's compact size and plug and play connectivity.

Setup of the Remora Mini is straightforward, simply plug the heat pump into an outdoor socket using the fitted mains cable and plug, connect the 32mm or 38mm hoses from your pool’s filter, switch on and set your desired water temperature.

Please note that the Remora Mini only operates in ambient air temperatures above 12 degrees, if the air temperature falls below this the unit will shut down.

Special offer available while stocks last, all units are brand new, boxed, and come complete with the full manufacturer’s warranty

Not sure what size heat pump you need?
Use our sizing guide or request a free quote

Key features

3kW heating capacity for June to August use on small pools up to 20m³

Mini design with compact footprint for easier placement, only 397mm high, 447mm wide and 320mm deep

Plug and Play convenience – fitted with 2.8m mains cable, RCD and UK plug – suitable for outdoor socket

32mm/38mm hose tail connectors

High efficiency performance, COP of 5.44, up to 3.21kW of heat for every kW used

Recommended for use in ambient temperatures above 12 degrees

Easy digital temperature control with LCD display

Auto operation and timer function

Quiet running, less than 32dB(A) at 10m

R32 gas for environmentally friendly operation

Aluminium evaporator with anti-corrosion Hydrophilic bluefin treatment

Flow switch prevents damage to the unit in event of no or low flow

Downloads

Specifications

Heating Capacity A26/W26
3.21 kW
Power Input A24/W26
0.59kW
COP A24/W26
5.44
Heating Capacity A15/W26
2.12 kW
Power Input A15/W26
0.52 kW
COP A15/W26
4.06
Max. Input Power
0.68 kW
Max. Current
3.09A
Electrical connection
2.8m cable, RCD and UK plug fitted
Voltage
230V
Refrigerant
R32
Noise Level (10m)
<32dB(A)
Fan Direction
Horizontal
Water Connections
32mm/38mm hose tail
Dimensions (L x W x H)
447mm x 320mm x 397mm
Nominal flow
1.30 m³/h

What is COP?

COP stands for Coefficient of Performance

COP is quoted as a number, such as 5.6

For each kW of energy input, 5.6 x kW would be output

The higher the output, the lower the running costs

Installation

If you are thinking of heating your pool you should cover the pool when not in use as 80% of heat loss occurs through surface evaporation, a separate solar or bubble cover is a worthwhile investment if you don’t have an existing cover.

With an above ground pool it is especially important to keep it covered as these pools are not well insulated against heat loss – additional insulation around the sides and bottom of an above-ground pool can help to retain valuable heat – in fact properly insulating your pool can extend your season or even reduce the size of heat pump required.

The Remora Mini 3kW is fitted with a 2.8m mains cable, RCD and plug as standard, making it suitable for outdoor sockets, this cable can be removed and the unit can be hardwired if required.

Water inlet and outlet connections are 32mm/38mm hose tail connectors.

If the flow rate through your heat pump is too high it can take longer to heat your pool or you may struggle to achieve your desired temperature, our bypass kit for above ground pools optimises the flow rate to maximise the heat transfer to your pool water. A bypass kit also allows the circulation and filtering of pool water without heating and for winterising your heat pump.

Your Remora Mini swimming pool heat pump should always be installed outside, restrictions on air flow around a heat pump such as dense vegetation or solid surfaces such as sheds, fences or walls will lead to a drop in efficiency and heating ability, it especially important that cooled air can be properly dispersed away from the unit.

While manufactured from high-quality materials including a corrosion resistant case, with a rotary compressor and an aluminium evaporator with corrosion resistant Hydrophilic bluefin treatment, the Mini is intended for Summer use only, the unit should be disconnected and stored in a shed or garage when not in use over the Winter.

The manufacturer literature may state that the heat pump should be positioned above the waterline, the assumption being that pools are in-ground, therefore the heat pump would sit at ground level.

If you have an above-ground pool please also position your heat pump at ground level (therefore below the waterline), there is no need to elevate the heat pump.

Two year parts and labour (return to base)

Seven years on the compressor and heat exchanger (parts only after year three)

Remora brand is exclusive to Automated Environmental Systems

Remora Mini 3kW Plug & Play Heat Pump for Small Above Ground Swimming Pools

£350 (£291.67 +VAT)

Save 31% | Was £504

Save £154

7 in stock Available for delivery from next working day

Bypass Kit

Universal Heat Pump Bypass Kit for Above Ground Pools
Hydro-Fit Universal Heat Pump Bypass Kit

131 in stock Available for delivery from next working day

-
+
£70.50 (£58.75 +VAT)

Fittings

38mm Black Vac Pool Hose
Black 38mm Vac Hose (per metre)

634 in stock Available for delivery from next working day

-
+
£2.50 (£2.08 +VAT)
Stainless Steel Hose Clip
Stainless Steel Hose Clip (Type W4, 9mm) - 30-45mm

194 in stock Available for delivery from next working day

-
+
£1 (£0.83 +VAT)

Accessories

Rubber Mounting Feet with Fixings (Unistrut Compatible)
Rubber Mounting Feet with Fixings (Unistrut Compatible) - 400MM KIT

2 in stock Available for delivery from next working day

-
+
£74.40 (£62 +VAT)
Floating Thermometer
Floating Thermometer

43 in stock Available for delivery from next working day

-
+
£4.50 (£3.75 +VAT)
Product code: 81213 Categories: , Tag:

Small UK Mainland (under £100) - from next working day £7.80

Standard UK Mainland (under £300) - from next working day £12

Free UK Mainland (over £300) - from next working day

Collect from our warehouse, Mon to Fri 9am to 5pm

Channel Islands and Isle of Man £70 (3-4 days)

Isle of Wight £30 (2 days)

Lower Highlands £30 (2 days)

Upper Highlands (mainland) £30 (3-4 days)

Scottish Offshore £35 (5-7 days)

Large and/or heavy items are dispatched on pallets

ALL heat pumps are dispatched on pallets

Delivery is to kerbside via lorry with tail lift

Pallet deliveries must be signed for

Parked cars, overhanging trees and narrow roads can prevent lorry access - please notify us of known access restrictions PRIOR to delivery

For full details see our delivery page

Product Description

The Remora Mini 3kW Plug & Play heat pump is perfect for heating small above-ground pools (<20m³) from June to August thanks to it's compact size and plug and play connectivity.

Setup of the Remora Mini is straightforward, simply plug the heat pump into an outdoor socket using the fitted mains cable and plug, connect the 32mm or 38mm hoses from your pool’s filter, switch on and set your desired water temperature.

Please note that the Remora Mini only operates in ambient air temperatures above 12 degrees, if the air temperature falls below this the unit will shut down.

Special offer available while stocks last, all units are brand new, boxed, and come complete with the full manufacturer’s warranty

Not sure what size heat pump you need?
Use our sizing guide or request a free quote

Key features

3kW heating capacity for June to August use on small pools up to 20m³

Mini design with compact footprint for easier placement, only 397mm high, 447mm wide and 320mm deep

Plug and Play convenience – fitted with 2.8m mains cable, RCD and UK plug – suitable for outdoor socket

32mm/38mm hose tail connectors

High efficiency performance, COP of 5.44, up to 3.21kW of heat for every kW used

Recommended for use in ambient temperatures above 12 degrees

Easy digital temperature control with LCD display

Auto operation and timer function

Quiet running, less than 32dB(A) at 10m

R32 gas for environmentally friendly operation

Aluminium evaporator with anti-corrosion Hydrophilic bluefin treatment

Flow switch prevents damage to the unit in event of no or low flow

Downloads

Specifications

Heating Capacity A26/W26
3.21 kW
Power Input A24/W26
0.59kW
COP A24/W26
5.44
Heating Capacity A15/W26
2.12 kW
Power Input A15/W26
0.52 kW
COP A15/W26
4.06
Max. Input Power
0.68 kW
Max. Current
3.09A
Electrical connection
2.8m cable, RCD and UK plug fitted
Voltage
230V
Refrigerant
R32
Noise Level (10m)
<32dB(A)
Fan Direction
Horizontal
Water Connections
32mm/38mm hose tail
Dimensions (L x W x H)
447mm x 320mm x 397mm
Nominal flow
1.30 m³/h

What is COP?

COP stands for Coefficient of Performance

COP is quoted as a number, such as 5.6

For each kW of energy input, 5.6 x kW would be output

The higher the output, the lower the running costs

Installation

If you are thinking of heating your pool you should cover the pool when not in use as 80% of heat loss occurs through surface evaporation, a separate solar or bubble cover is a worthwhile investment if you don’t have an existing cover.

With an above ground pool it is especially important to keep it covered as these pools are not well insulated against heat loss – additional insulation around the sides and bottom of an above-ground pool can help to retain valuable heat – in fact properly insulating your pool can extend your season or even reduce the size of heat pump required.

The Remora Mini 3kW is fitted with a 2.8m mains cable, RCD and plug as standard, making it suitable for outdoor sockets, this cable can be removed and the unit can be hardwired if required.

Water inlet and outlet connections are 32mm/38mm hose tail connectors.

If the flow rate through your heat pump is too high it can take longer to heat your pool or you may struggle to achieve your desired temperature, our bypass kit for above ground pools optimises the flow rate to maximise the heat transfer to your pool water. A bypass kit also allows the circulation and filtering of pool water without heating and for winterising your heat pump.

Your Remora Mini swimming pool heat pump should always be installed outside, restrictions on air flow around a heat pump such as dense vegetation or solid surfaces such as sheds, fences or walls will lead to a drop in efficiency and heating ability, it especially important that cooled air can be properly dispersed away from the unit.

While manufactured from high-quality materials including a corrosion resistant case, with a rotary compressor and an aluminium evaporator with corrosion resistant Hydrophilic bluefin treatment, the Mini is intended for Summer use only, the unit should be disconnected and stored in a shed or garage when not in use over the Winter.

The manufacturer literature may state that the heat pump should be positioned above the waterline, the assumption being that pools are in-ground, therefore the heat pump would sit at ground level.

If you have an above-ground pool please also position your heat pump at ground level (therefore below the waterline), there is no need to elevate the heat pump.

Two year parts and labour (return to base)

Seven years on the compressor and heat exchanger (parts only after year three)

Remora brand is exclusive to Automated Environmental Systems

We use cookies to offer you a better browsing experience and to allow third parties to customise the marketing content you see across websites and social media