Not sure what size heat pump you need? Use our sizing guide or request a free quote
Key features
3kW heating capacity for June to August use on small pools up to 20m³
Mini design with compact footprint for easier placement, only 397mm high, 447mm wide and 320mm deep
Plug and Play convenience – fitted with 2.8m mains cable, RCD and UK plug – suitable for outdoor socket
32mm/38mm hose tail connectors
High efficiency performance, COP of 5.44, up to 3.21kW of heat for every kW used
Recommended for use in ambient temperatures above 12 degrees
Easy digital temperature control with LCD display
Auto operation and timer function
Quiet running, less than 32dB(A) at 10m
R32 gas for environmentally friendly operation
Aluminium evaporator with anti-corrosion Hydrophilic bluefin treatment
Flow switch prevents damage to the unit in event of no or low flow
Downloads
Specifications (.pdf)
Manual (.pdf)
Specifications
Heating Capacity A26/W26 |
3.21 kW |
Power Input A24/W26 |
0.59kW |
COP A24/W26 |
5.44 |
Heating Capacity A15/W26 |
2.12 kW |
Power Input A15/W26 |
0.52 kW |
COP A15/W26 |
4.06 |
Max. Input Power |
0.68 kW |
Max. Current |
3.09A |
Electrical connection |
2.8m cable, RCD and UK plug fitted |
Voltage |
230V |
Refrigerant |
R32 |
Noise Level (10m) |
<32dB(A) |
Fan Direction |
Horizontal |
Water Connections |
32mm/38mm hose tail |
Dimensions (L x W x H) |
447mm x 320mm x 397mm |
Nominal flow |
1.30 m³/h |
What is COP?
COP stands for Coefficient of Performance
COP is quoted as a number, such as 5.6
For each kW of energy input, 5.6 x kW would be output
The higher the output, the lower the running costs
Installation
If you are thinking of heating your pool you should cover the pool when not in use as 80% of heat loss occurs through surface evaporation, a separate solar or bubble cover is a worthwhile investment if you don’t have an existing cover.
With an above ground pool it is especially important to keep it covered as these pools are not well insulated against heat loss – additional insulation around the sides and bottom of an above-ground pool can help to retain valuable heat – in fact properly insulating your pool can extend your season or even reduce the size of heat pump required.
The Remora Mini 3kW is fitted with a 2.8m mains cable, RCD and plug as standard, making it suitable for outdoor sockets, this cable can be removed and the unit can be hardwired if required.
Water inlet and outlet connections are 32mm/38mm hose tail connectors.
If the flow rate through your heat pump is too high it can take longer to heat your pool or you may struggle to achieve your desired temperature, our bypass kit for above ground pools optimises the flow rate to maximise the heat transfer to your pool water. A bypass kit also allows the circulation and filtering of pool water without heating and for winterising your heat pump.
Your Remora Mini swimming pool heat pump should always be installed outside, restrictions on air flow around a heat pump such as dense vegetation or solid surfaces such as sheds, fences or walls will lead to a drop in efficiency and heating ability, it especially important that cooled air can be properly dispersed away from the unit.
While manufactured from high-quality materials including a corrosion resistant case, with a rotary compressor and an aluminium evaporator with corrosion resistant Hydrophilic bluefin treatment, the Mini is intended for Summer use only, the unit should be disconnected and stored in a shed or garage when not in use over the Winter.
The manufacturer literature may state that the heat pump should be positioned above the waterline, the assumption being that pools are in-ground, therefore the heat pump would sit at ground level.
If you have an above-ground pool please also position your heat pump at ground level (therefore below the waterline), there is no need to elevate the heat pump.
Two year parts and labour (return to base)
Seven years on the compressor and heat exchanger (parts only after year three)
Remora brand is exclusive to Automated Environmental Systems